Septic Tank Size Calculator

Choose a home and its bedrooms, or another building and its daily water use, to see the septic tank capacity you need.

How it is calculated

The tool follows the EPA Onsite Wastewater Treatment Systems Manual (2002), a US practice. For a one- or two-family home the tank is read from the bedroom table of the International Private Sewage Disposal Code that the manual reproduces as Table 4-13: 1 or 2 bedrooms 750 gallons, 3 bedrooms 1,000, 4: 1,200, 5: 1,425, 6: 1,650, 7: 1,875, 8: 2,100. The manual adds that many states have set 1,000 gallons or more as the minimum; the tool says so beside a 750-gallon result rather than changing it. The table stops at 8 bedrooms. For other buildings the manual gives a rule of thumb of two to three times the estimated design flow: daily flow = people × gallons per person and tank = daily flow × multiple. Liters are gallons × 3.785411784. With the unit system set to metric, the water use per person is in liters per day (divided by 3.785411784 to gallons, so the same building gets the same tank) and the tank and the daily flow are shown in liters only; on US units they are shown in gallons, with the tank and the daily flow in liters beside them. A fractional head or bedroom count, zero people or a zero usage or multiple gives no result. Local rules differ on minimum size, compartments and how a house is counted, so check the regulations where you live.

Worked example

A three-bedroom home: Table 4-13 of the EPA manual gives 1,000 gallons, which is 1,000 × 3.7854 = 3,785 L. A two-bedroom home gets 750 gallons in the table, though many states require at least 1,000, and a five-bedroom home 1,425. For a building other than a home with 8 people at 70 gallons a day, the daily flow is 8 × 70 = 560 gallons, and at 2 times the flow the tank is 1,120 gallons (3 times: 1,680).

Try this example →

Common mistakes

  • Sizing a house by the number of people. Codes size one- and two-family homes by bedrooms, because a bedroom can be occupied later; choose the home option.
  • Typing liters per person per day while the unit system is on US units: 150 liters read as 150 gallons gives a tank about four times too big. Choose metric to enter liters, or enter about 40 gallons.
  • Expecting the table to be the legal minimum where you live: many states require at least 1,000 gallons even for one or two bedrooms.
  • Using a multiple outside 2 to 3 for another building without a reason: that range is the EPA rule of thumb for a 24-hour retention when the tank is ready for pumping.
  • Treating the result as the final design: it ignores local code, soil conditions, garbage disposal use and the drain field size.

Sources

About this calculator

Septic tank sizing determines the minimum capacity a building's wastewater system needs so that solids have time to settle and partially decompose before the liquid effluent flows out to the drain field. For one- and two-family homes, plumbing codes give the tank volume by number of bedrooms: the table the EPA Onsite Wastewater Treatment Systems Manual reproduces runs from 750 US gallons for one or two bedrooms through 1,000 for three to 2,100 for eight, and many states set 1,000 gallons or more as the minimum. For other buildings the manual's rule of thumb is two to three times the estimated daily design flow.

Homeowners, builders and septic installers need this figure when installing a new system, replacing an undersized tank, or adding bedrooms/bathrooms to a home, because a septic tank that's too small doesn't give solids enough time to settle, leading to solids escaping into the drain field and clogging it — a failure that is expensive and disruptive to fix, since it usually means digging up and replacing the entire leach field.

Was this helpful?

You can pick up to 3 reactions.

Comments

  • Be the first to comment.

Popular calculators

All Calculators