Radiation Dose Equivalent Calculator

Enter the absorbed dose and radiation type to find the dose equivalent in sieverts.

How it is calculated

The absorbed dose D is entered in grays (Gy) and the radiation type is picked from a list. The tool multiplies by the quality factor of the US Nuclear Regulatory Commission table, 10 CFR 20.1004 Table 1004(b).1: H = D × Q, giving the dose equivalent H in sieverts (Sv). The factors are 1 for X-rays, gamma rays and beta particles, 10 for neutrons of unknown energy, 10 for high-energy protons and 20 for alpha particles. A type outside the list gives no result. The result is also shown in millisieverts (mSv = Sv × 1000) along with the factor used. Negative doses give no result, and the figures are rounded to four decimals; a smaller dose keeps its significant digits or is written in scientific notation (0.00001 Gy of gamma is 0.00001 Sv, 0.0100 mSv). When the neutron energy is known, the same regulation's Table 1004(b).2 gives mean factors from 2 for thermal neutrons to 11 near 1 MeV, and ICRP Publication 103 uses 2 for protons and a continuous function of neutron energy, so for neutrons and protons this tool gives the NRC figure, not the ICRP one. Dose equivalent describes radiation type only, not which organs were exposed.

Worked example

Suppose 0.002 Gy (2 mGy) of alpha radiation is absorbed. Alpha particles have a quality factor of 20. The calculation is H = 0.002 × 20 = 0.04 Sv. The tool shows 0.0400 Sv, which is 0.04 × 1000 = 40.0000 mSv, with Q = 20. The same 0.002 Gy of gamma radiation would give only 0.0020 Sv (2 mSv), which shows why the type matters even when the absorbed dose is identical.

Try this example →

Common mistakes

  • Entering a dose in sieverts or millisieverts. The input is the absorbed dose in grays; typing a value already in Sv applies the weighting twice for heavy particles.
  • Entering milligray as gray. 5 mGy is 0.005 Gy, not 5; a factor-of-1000 slip changes the answer from 5 mSv to 5 Sv for gamma rays.
  • Mixing the NRC and ICRP systems. The proton factor is 10 here (NRC) and 2 under ICRP 103, so a figure from this tool and one from an ICRP-based report can differ for protons and neutrons.
  • Reading a 0.0000 Sv result as zero exposure. Small doses are rounded at four decimals in the sievert line, so use the millisievert value instead.
  • Treating the result as a whole-body risk figure. It only applies the radiation-type factor; it does not weight different organs or tissues.

Sources

About this calculator

Radiation exposure is first measured as absorbed dose, in grays (Gy) — the physical energy deposited per kilogram of tissue — but different types of radiation do different biological damage per gray absorbed. The dose equivalent, in sieverts (Sv), corrects for this by multiplying the absorbed dose by a factor for the radiation type. This tool follows one system throughout, the quality factors of the US Nuclear Regulatory Commission in 10 CFR 20.1004: 1 for X-rays, gamma rays and beta particles, 10 for neutrons of unknown energy and for high-energy protons, and 20 for alpha particles, which cause far more damage per unit of deposited energy. The ICRP (International Commission on Radiological Protection) system in Publication 103 gives the same 1 and 20 but 2 for protons and a neutron factor that depends on the neutron energy, so for those two types the figures differ.

This conversion is central to radiology, nuclear medicine, and radiation safety programs, where sieverts are used to set occupational exposure limits, report patient doses from CT scans or radiotherapy, and compare risks across radiation sources — from a chest X-ray (a fraction of a millisievert) to occupational limits for radiation workers (tens of millisieverts per year).

Was this helpful?

You can pick up to 3 reactions.

Note from the editors

High-energy protons and neutrons of unknown energy share one factor here, so 0.003 Gy of either reads 0.0300 Sv, or 30.0000 mSv. If your instrument reads in milligray, divide by 1000 first. For questions about a real person's exposure, ask a radiation protection officer. Which radiation type are you converting most often?