Air Conditioner Sizing Calculator

Enter the room area, ceiling height, sun exposure and number of people to size your air conditioner.

How it is calculated

Area is entered in square feet and the ceiling in feet, or, with Units set to Metric, in square meters and meters (1 m² = 10.764 sq ft; the chart itself is in square feet). Occupants are a whole number, at most one person per 5 sq ft (0.46 m²) of floor, the densest standing load building codes allow. The capacity starts from the ENERGY STAR room air conditioner chart, the same one the BTU calculator uses: 100 up to 150 sq ft 5,000 BTU/h, 150 up to 250 6,000, 250 up to 300 7,000, 300 up to 350 8,000, and so on up to 2,000–2,500 sq ft at 34,000 (below 100 sq ft the smallest row is used; above 2,500 there is no figure). Then ENERGY STAR's adjustments: heavily shaded −10%, very sunny +10%, 600 BTU/h for each person beyond two who regularly use the room, and 4,000 BTU/h in a kitchen. The result is also shown in tons (BTU/h ÷ 12,000) and kilowatts (BTU/h × 0.000293). ENERGY STAR's figures are for an 8-foot ceiling and it gives no adjustment for a higher one, so the ceiling height only adds a note. A fractional head count, a zero or negative area or height, a negative occupant count and more people than the floor can hold produce no result. Climate, insulation and window area are not modeled, so treat the figure as a starting point.

Worked example

A 350 ft² room with a 9 ft ceiling, very sunny, with 4 people. The ENERGY STAR chart row “350 up to 400” sq ft gives 9,000 BTU/h. Very sunny adds 10%: 9,900. The two people beyond the first two add 2 × 600 = 1,200, so the total is 11,100 BTU/h, which is 0.93 tons of cooling or 3.25 kW. The chart is for an 8 ft ceiling and ENERGY STAR gives no figure for a 9 ft one, so the tool notes it without raising the capacity. In practice you would pick the nearest standard unit at or just above this figure.

Try this example →

Common mistakes

  • Typing square meters with Units left on US: the area is then read as square feet, so a 30 m² room (about 323 sq ft, chart figure 8,000 BTU/h) typed as 30 falls below the chart and gets its smallest figure, 5,000 BTU/h. Choose Metric for square meters and meters.
  • Expecting a taller ceiling to raise the figure: ENERGY STAR's chart is for 8-foot ceilings and gives no adjustment for higher ones, so the tool only notes it.
  • Counting every person: only occupants beyond the first two add load, and visitors who stay briefly do not belong in the count.
  • Rounding down to a smaller unit to save money: an undersized unit may never reach the set temperature on hot days.
  • Ignoring heat sources the formula does not know about, such as large west-facing windows or a hot attic above; for a kitchen choose the kitchen option.

Sources

About this calculator

Air conditioner sizing calculates the cooling capacity, measured in BTU/hr (British Thermal Units per hour), that a room needs to reach and hold a comfortable temperature. The baseline is the ENERGY STAR sizing chart, which steps the capacity with floor area (7,000 BTU/hr for 250 up to 300 sq ft, 8,000 for 300 up to 350) for an 8-foot ceiling, then adjusted for sun exposure (you choose shaded, average or sunny: a very sunny room, such as one facing south or west, gets 10% more capacity and a heavily shaded one 10% less), and occupancy, since HVAC guidelines add roughly 600 BTU for each additional person regularly in the room beyond the first two, because bodies generate heat, and a unit in a kitchen gets 4,000 BTU more. ENERGY STAR gives no figure for ceilings above 8 feet, so a taller ceiling is noted rather than scaled.

Homeowners and HVAC installers use this sizing before buying a window unit, split system or portable AC, because an undersized unit runs constantly without ever reaching the target temperature, while an oversized unit cycles on and off too quickly (short-cycling), which wastes energy and fails to properly dehumidify the room — bigger is not automatically better with air conditioning.

Floor area in square feet (or square meters with Units set to Metric), how sunny the room is, how many people use it and whether it is a kitchen are combined, through the same chart as the BTU calculator, into the BTU/hr capacity to shop for, also given in tons and kW.

Was this helpful?

You can pick up to 3 reactions.

Comments

  • Be the first to comment.

Popular calculators

All Calculators