15.9 Ω
50–200 pF
50.00 MHz
101.3 nH
TI SLPA010: R = ½ √(Lp/Cp) = 1/(4π Fp Cp) for optimal damping, Csnub between ½ and 2 × Cp (½ Cp on a good layout). A starting point: tune on the board and check the resistor's power rating.

How it is calculated

You enter the measured ringing frequency Fp in MHz and the estimated parasitic capacitance Cp in pF of the switching node (for a synchronous buck, TI suggests the sync FET's COSS at VDS = VIN). The tool follows TI application report SLPA010: the parasitic inductance is Lp = 1 ÷ ((2π Fp)² × Cp); the snubber capacitor is chosen between ½ and 2 × Cp (½ Cp is enough on a properly designed board, a poor layout may need more); and the resistor for optimal damping of the parallel LCR circuit is R = ½ √(Lp ÷ Cp) = 1 ÷ (4π × Fp × Cp).

R is shown in ohms to one decimal, the capacitor range in picofarads, Lp in nanohenries and the frequency echoed to two decimals. Both inputs must be above zero. The values are a starting point to tune on the board: a larger R damps the ringing faster, a smaller one limits the peak. Almost all the snubber's loss is burned in the resistor, so check its power rating separately.

Worked example

Suppose a switching node rings at 50 MHz and its parasitic capacitance is estimated at 100 pF. In SI units that is 50 × 106 Hz and 100 × 10−12 F. The parasitic inductance is Lp = 1 ÷ ((2π × 50 × 106)² × 100 × 10−12) ≈ 101.3 nH. TI's resistor for optimal damping is ½ √(Lp ÷ Cp) = 1 ÷ (4π × 50 × 106 × 100 × 10−12) = 1 ÷ 0.0628 = 15.9 Ω, and the capacitor goes between ½ and 2 × 100 pF, that is 50 to 200 pF. A 15 or 16 Ω resistor with a 50 pF capacitor on a tidy layout, or up to 200 pF on a poor one, is a sensible starting pair to tune on the bench.

Try this example →

Common mistakes

  • Entering the ringing frequency in Hz or kHz. The field is MHz, so 50 MHz is 50, not 50,000,000.
  • Entering the parasitic capacitance in nF. The field is in pF, and 0.1 nF is 100.
  • Using the switching frequency of the converter rather than the ringing frequency read from the oscilloscope trace at the node.
  • Taking the largest capacitor by default. The snubber's loss grows with its capacitance, so start near ½ Cp and go up only if the ringing is not tamed.
  • Ignoring the resistor power rating. The snubber converts ringing energy to heat on every switching cycle, and that dissipation is not given here.

Sources

About this calculator

In switching power converters, every trace, pad and component lead has a bit of stray inductance and capacitance, and when a MOSFET or diode switches off abruptly, that parasitic LC network rings — the voltage overshoots and oscillates at a frequency set by the parasitic inductance and capacitance before settling. An RC snubber tames this ringing by adding a resistor in series with a capacitor across the ringing node: following TI application report SLPA010, the capacitor is chosen between half and twice the parasitic capacitance (half is enough on a well laid-out board) and the resistor is R = ½ √(L_parasitic/C_parasitic) = 1/(4π × f_ringing × C_parasitic), the value that damps the parasitic LC ring best, turning the ringing energy into heat without slowing down the switching edge too much.

Power electronics engineers add snubbers to reduce electromagnetic interference (EMI), protect switching devices from voltage spikes beyond their rated breakdown voltage, and pass EMC compliance testing in designs like flyback converters, motor drives and switch-mode power supplies. Measure the ringing frequency on the scope, estimate the parasitic capacitance, and it suggests the RC snubber values to start with; they are a starting point to fine-tune on the board.

Was this helpful?

You can pick up to 3 reactions.

Note from the editors

The resistor value moves inversely with both inputs, so the measurement quality matters. With 100 pF parasitic capacitance the tool gives 39.8 ohm at a 20 MHz ring but 19.9 ohm at 40 MHz, and the capacitor range stays 50 to 200 pF. A probe with a long ground lead can shift the ring you read, so measure with a short ground spring. The power rating of the resistor still has to be checked separately. What converter topology are you tuning?