Pool Heating Cost Calculator

Enter pool volume, the temperature rise you want, heater efficiency and your energy price.

Result

How it is calculated

Volume is in US gallons and the temperature rise in °F, or, with the unit system set to metric, liters and °C; the heater efficiency is in percent (1 to 100) and the price is per kWh of the energy the heater uses. Water weighs 8.34 lb per gallon and needs 1 BTU per pound per °F, so heat needed (BTU) = gallons × 8.34 × rise. With 1 kWh = 3,412.142 BTU, net kWh = BTU / 3,412.142. In metric the tool converts the liters to gallons (÷ 3.785411784) and the °C rise to °F (× 1.8, a temperature difference has no 32 offset) and runs the same formula; that is 4.184 kJ, or 1.1622 Wh, per liter per °C (water's specific heat of about 4.186 kJ/kg·K at 1 kg per liter), so net kWh = liters × rise × 0.0011622 and the same pool gives the same energy and cost in both systems. The energy used is kWh in = net kWh / efficiency. Then cost = kWh in × price and cost per degree = cost / rise, per °F on US units and per °C in metric (1.8 times as much). The heat needed is shown in MMBtu on US units and in kWh in metric. Efficiency cannot exceed 100%, so a heat pump with a COP of 4 cannot be entered directly: you can instead divide your electricity price by the COP and enter 100. Heat lost to air, wind and evaporation, and the cost of keeping the pool warm, are not included.

Worked example

A 15,000-gallon pool, a 10 °F rise, an 85% efficient heater and energy at 0.15 per kWh. Heat needed = 15,000 × 8.34 × 10 = 1,251,000 BTU, which is 1.25 MMBtu or 366.6 kWh of net heat. Energy used = 366.6 / 0.85 = 431.33 kWh. Cost = 431.33 × 0.15 = $64.70. That is $6.47 per °F. Heating by 20 °F would double both the energy and the cost.

Try this example →

Common mistakes

  • Typing liters or a °C rise while the unit system is on US units. The fields then read US gallons and °F, so a 60 m³ pool must be about 15,850 gallons and a 10 °C rise is 18 °F; switch the unit system to metric instead and enter 60000 and 10.
  • Entering cubic meters in metric. The field is in liters, so a 60 m³ pool is 60000.
  • Entering a heat pump's COP (such as 4) as efficiency: the field accepts up to 100 and returns nothing above it.
  • Assuming the result is the cost of a season: it is the cost of the initial rise only, and it excludes the heat the pool loses every day to air and evaporation.
  • Using the gas price per therm or per cubic meter while the field wants a price per kWh.

Sources

About this calculator

Heating a pool by a given temperature rise takes a fixed amount of energy determined by physics — energy = pool volume × water's specific heat × temperature rise — and the calculator then divides that by your heater's efficiency (a percentage of up to 100), since gas heaters typically run at 80–95% efficiency and electric resistance heaters near 100%. Heat pumps deliver a coefficient of performance of roughly 4–6 (meaning they move 4–6 units of heat per unit of electricity consumed), which is above 100% and so cannot be entered as an efficiency; to estimate a heat pump, set the efficiency to 100% and divide the energy and cost by its COP. The energy result in kWh is then multiplied by your local energy price to get the cost.

Pool owners run this calculation when comparing heater types before purchase, since a heat pump's much higher COP can make it dramatically cheaper to run than a gas heater or electric resistance heater despite a higher upfront cost, or when deciding whether it's worth heating the pool at all for a short swim season.